Mortise Lock Exit Device

8000 Series – Heavy Duty – Grade 1


8620S (SMOOTH)/8820S (GROOVED)
Panic-Rated Mortise Lock Exit Devices


8620F (SMOOTH)/8820F (GROOVED)
Fire-Rated Mortise Lock Exit Devices


Specifications

  • Device Lengths Short (36”) actual end to end length 33-15/32” (850 mm)
    Long (48”) actual end to end length 44-3/4” (1137 mm)
  • Door WidthsShort (36”) for 29” to 36” (736 mm to 914 mm) door size
    Long (48”) for 33” to 48” (838 mm to 1219 mm) door size
  • Min. Stile Width4-1/4” (108 mm)
  • Latch BoltStainless steel two-piece mechanical 3/4” (19 mm) with anti-friction inset
    and auxiliary deadlocking latch
  • Strikes Universal curved lip, non-handed, 818 (panic), 828 (fire). Optional 831(panic)
    or 832 (fire) flat ANSI Strike
  • Dogging Panic device – Hex key dogging (RD) standard
    Fire device – No dogging (ND)
  • Dogging OptionsCylinder Dogging (CD)
    Less Dogging (LD)
  • FastenerPanic device – Machine screws furnished standard for HMD.
    For wood doors sex nuts and bolts (SNB) can be ordered separately
    Fire Exit Device – Sex nuts and bolts (SNB) supplied standard
  • Mounting Height Standard device centerline from finished floor is 40” (1016 mm)
  • ProjectionPush bar Neutral: 3-1/16” (78 mm),Push bar Depressed: 2-19/32” (66 mm)

818

Standard for:
8620S
8820S
For Use on:
1-3/4” standard or
2-1/4” thick single door, and
2-1/4” double door with over-lapping astragal and coordinator

828

Standard for:
8620F
8820F
For Use on:
1-3/4” standard or
2-1/4” thick single door, and
2-1/4” double door with over-lapping astragal and coordinator